D2×2 SM Specifications

Parameters

Unit

FSW-D2×2-S

Wavelength Range

nm

1260 ~ 1650

Test Wavelength

nm

1310 / 1550

Insertion Loss 1, 2

dB

Typ: 1.0    Max: 1.5

Return Loss 1, 2

dB

≥ 50

Crosstalk 1

dB

 SM ≥ 65

PDL

dB

≤0.05

WDL

dB

≤0.25

Repeatability

dB

≤±0.05

Operating Voltage

V

3.0  or  5.0

Durability

Cycles

≥ 10 Million

Switching Time

ms

≤8

Optical Power

mW

≤500

Operating Temperature

¡æ

-5 ~ +70

Storage Temperature

¡æ

-40 ~ +85

Relative Humidity

%

5 ~ 95

Weight

g

16

Dimension

mm

(L)28.5×(W)12.6×(H)8.7 ±0.2

Note:   1  Within operating temperature and SOP.

2  Excluding Connectors.

 

D2×2 MM Specifications

Parameters

Unit

FSW-D2×2-M

Wavelength Range

nm

850±40 / 1300±40

Test Wavelength

nm

850 / 1300

Insertion Loss 1, 2

dB

Typ: 1.0    Max: 1.5

Return Loss 1, 2

dB

≥ 30

Crosstalk 1

dB

≥ 35

PDL

dB

≤0.05

WDL

dB

≤0.25

Repeatability

dB

≤±0.02

Operating Voltage

V

3.0  or  5.0

Durability

Cycles

≥ 10 Million

Switching Time

ms

≤8

Optical Power

mW

≤500

Operating Temperature

¡æ

-5 ~ +70

Storage Temperature

¡æ

-40 ~ +85

Relative Humidity

%

5 ~ 95

Weight

g

14

Dimension

mm

(L)27.0×(W)12.6×(H)8.2 ±0.2

Note:   1  Within operating temperature and SOP.

2  Excluding Connectors.

 

--Ordering Information: 

FSW-D2×2-A-B-C-D-E-F-G

A

B

C

D

E

F

G

Fiber Type

Operating Voltage

Switch Type

Test Wavelength

Tube Type

Fiber Length

(Include connector)

Connector

SM: SM, 9/125

M5:MM, 50/125

M6:MM, 62.5/125

X: Others

3: 3V

5: 5V

L: Latching

N: Non-latching

850: 850nm

1310: 1310nm

1550: 1550nm

1310/1550:1310/1550nm

X:Others

25:250um

90:900um

X: Others

05: 0.5m±5cm

10: 1.0m±5cm

15: 1.5m±5cm

X: Others

OO:None

FP:FC/PC

FA: FC/APC

SP: SC/PC

SA: SC/APC

STP: ST/PC

LP: LC/PC

LA: LC/APC

X: Others

 

 

 

 

 

 

Important Notice

Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.
The publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.

Search

ÍøÕ¾µØͼ