+86-028-85255257
Product PN:
²úÆ·ÐÎò
Athermal AWG series products take silica-on-silicon planar technology and it is built with high performance and reliability, which can be used in general DWDM systems. Based on the athermal design and packing, it is totally passive product which does not require any electrical power or temperature control. For 100G AAWG Mux/Demux, it supports up to 48-CH based on a single chipset. Customized wavelengths, package and fiber options are also available.
Ìصã/Features
µÍÏûºÄ/Low Insertion Loss
¿íÊÂÇé´ø¿í/Wide pass band
¸ßͨµÀ¸ôÀë¶È/High Channel Isolation
¸ßÎȹÌÐԺͿɿ¿ÐÔ/High Stability and reliability
Ó¦ÓÃ/Applications
²¨·Ö¸´ÓÃÍøÂç/WDM Network
µçÐÅͨѶ/Telecommunication
½ÓÈëÍø/Access Network
¼«ÏÞÌõ¼þ/Absolute Maximum Ratings
²ÎÊý/Parameters |
Ìõ¼þ/Conditions |
¹æ¸ñ/Specifications |
µ¥Î»/Unit |
|
Min. |
Max. |
|||
ÊÂÇéζÈ/Operating Temperature |
|
-5 |
65 |
oC |
ÊÂÇéʪ¶È/Operating Humidity |
ÎÞÀäÄýÇéÐÎ/Non-Condensing Environment |
0 |
95 |
%RH |
´æ´¢Î¶È/Storage Temperature |
|
-40 |
85 |
oC |
´æ´¢Êª¶È/Storage Humidity |
ÎÞÀäÄýÇéÐÎ/Non-Condensing Environment |
0 |
95 |
%RH |
¹âѧÐÔÄÜ/Optical Specifications
²ÎÊý/Parameters |
Ìõ¼þ/Conditions |
¹æ¸ñ/Specifications |
µ¥Î»/Unit |
||
Min. |
Typ. |
Max. |
|||
ͨµÀÊý/Number of Channels |
|
96 |
CH |
||
ͨµÀ¾àÀë/Number Channel Spacing |
|
50 |
GHz |
||
ITU ƵÂÊ/ITU Frequency |
On ITU grid in C-band Even |
196.00 |
|
192.05 |
THz |
ITU²¨³¤/ITU Wavelength |
On ITU grid in C-band Even. |
1529.553 |
|
1561.013 |
nm |
ÖÐÑ벨³¤´ø¿í/CenterWavelength Channel Passband |
Centered at each ITUchannel frequency |
± 0.1 |
nm |
||
3dB´ø¿í/3dB Channel Bandwidth |
Clear channel bandwidth defined by passband shape. For each Channel. |
0.25 |
|
|
nm |
20dB´ø¿í/20dB Channel Bandwidth |
Clear channel bandwidth defined by passband shape. For each channel. |
|
|
0.8 |
nm |
ITU²¨³¤Í¨µÀ²åËð/ Optical Insertion Loss at ITU grid |
Defined as the minimum transmission at ITU wavelength for all channels. For each channel, at all temperatures and polarizations with connectors. |
|
|
7.0 |
dB |
ÏàÁÚͨµÀ¸ôÀë¶È/ Adjacent Channel Isolation |
Ratio of peaktransmission to themaximum transmissionover both adjacent ITUwavelengths |
20 |
|
|
dB |
·ÇÏàÁÚͨµÀ¸ôÀë¶È/ Non-Adjacent,Channel Isolation |
Ratio of peaktransmission in channel passband to themaximum transmissionover all non-adjacentITU wavelength |
30 |
|
|
dB |
×Ü´®ÈÅ/Total Crosstalk |
Ratio of power inchannel to power in allother ITU wavelength |
17 |
|
|
dB |
²åËðÒ»ÖÂÐÔ/ Insertion Loss Uniformity |
The difference between the maximum and minimum of passbandacross all channels |
|
|
1.7 |
dB |
Æ«ÏòÐÔ/Directivity(Mux Only) |
Ratio of reflected power out of any channel(other than channel n)to power in from the input channel n |
40 |
|
|
dB |
»ØËð/Optical Return loss |
Input & output ports |
40 |
|
|
dB |
Æ«ÕñÏà¹ØÏûºÄ/ Polarization Dependent Loss in Clear Channel Band |
Worst-case value measured in ± 20GHz around ITU wavelength for each port. |
|
|
0.9 |
dB |
Æ«Õñģʽɫɢ Polarization Mode Dispersion |
Maximum differentialgroup delay withinreference ITUwavelength |
|
|
1.0 |
ps |
É«¶ÈÉ«É¢/Chromatic Dispersion |
Maximum change rateof group delay versuswavelength withinreference ITUwavelength |
-35 |
|
+35 |
ps/nm |
Note: Typical channel plan: ITU wavelengths 100G C20(1561.42nm)-C59(1530.33nm).
»úе³ß´ç,¹âÏËÊä³öºÍÁ¬ÌÖÂÛÉèÖÃ/Mechanical Dimensions, Fiber Coding and Connector Specifications
³ß´ç/Dimensions |
120 x 70 x 10/484 x 200 x 44 |
mm |
|||||||||||||
¹âÏËÀàÐÍ/Fiber Type |
¹«¹²¶Ë/Common SMF-28e fiber with 900um loose tube/ SMF-28e ¼Ó900umËÉÌ×¹Ü Í¨µÀ¶Ë/Channels: SMF-28eRibbons |
||||||||||||||
¹âÏ˳¤¶È/Fiber Length |
ÊäÈë¶Ë/Common |
1000mm ± 50mm with 900um loose tube/ÊäÈëÏ˳¤1000mm ± 50mm 900umÌ×¹Ü |
|||||||||||||
Êä³ö¶Ë/Channels |
Ribbon 500mm± 20 mm and Fan out 500mm± 30mm with 900um loose tube /Êä³ö´øÏË500mm± 20 mm£¬¼Ó·ÖÖ§Æ÷Ï˳¤500mm± 30mm |
||||||||||||||
¹«¹²¶Ë/Common |
ÑÕÉ«/Color |
°×/white |
|||||||||||||
´øÏ˱êʶ/RibbonIdentification |
´øÏË×îºóÌùÊýÂëÌù±êʶ /Label with ribbon number will be placed close to end-points |
||||||||||||||
ÅþÁ¬Æ÷ÀàÐÍ/Connector Options |
ÊäÈë¶Ë/Common |
LC/UPC |
|||||||||||||
Êä³ö¶Ë/Channels |
LC/UPC |
||||||||||||||
´øÏ˹âÏ˱êʶ/Fiber Identification in Ribbon |
1 |
˦/Blue |
2 |
³È/Orange |
3 |
ÂÌ/Green |
4 |
ºÖ/Brown |
5 |
»Ò/Grey |
6 |
°×/White |
|||
7 |
ºì/Red |
8 |
ºÚ/Black |
9 |
Ȯ/Yellow |
10 |
×Ï/Purple |
11 |
·Û/Pink |
12 |
Ë®/Aqua |
||||
*¿É°´¿Í»§ÒªÇó¶¨ÖÆ/Customized design available |
¶©¹ºÐÅÏ¢/Ordering Information
FT-13 |
XAWG |
X |
XX |
X |
XXX |
X |
X |
X |
XX |
|
Type |
Band |
Number of Channels |
Spacing |
1st Channel |
Chip Type |
Package |
Fiber Length (Total Length) |
In/Out Connector |
GAWG=Gaussian AWG |
C=C-Band L=L-Band D=C+L-Band X=Customize |
16=16-CH 32=32-CH 40=40-CH 48=48-CH 96=96-CH XX=Special |
1=100G 2=200G 5=50G X=Special |
C62=C62 H61=H61 C60=C60 H59=H59 . XXX=special |
G=Gaussian F=Flat Top |
M=Module R=Rack X=Special |
1=0.5m 2=1m 3=1.5m 4=2m X=Specify |
0=None 1=FC/APC 2=FC/PC 3=SC/APC 4=SC/PC 5=LC/APC 6=LC/PC 7=ST/UPC X=Specify |
Important Notice
Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.
The publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.