×ðÁú¿­Ê±×îÐÂƽ̨µÇ¼

±ê×¼¹âÄ£¿é

±ê׼ЭÒé¹âÄ£¿é

¼æÈÝЭÒé¹âÄ£¿é

ÆäËüÖÖÀà¹âÆ÷¼þ

ÊÖÒÕÖ§³Ö

100G BASE-LR4/OTU4 CFP Transceiver

100G BASE-LR4/OTU4 CFP Transceiver

0.0/5 rating (0 votes)

Description

Description

FT-MTRC-DG3CA CFP transceivers are designed for use in 100Gigabit Ethernet links and OTU4 over 10km single module fiber, and it compliant to the CFP MSA and IEEE 802.3ba 100GBASE-LR4. Digital diagnostics are available via MDIO as specified in the CFP MSA Management Interface Specification.

The transceiver's designs are optimized for high performance and cost efficiency to provide customers the best solutions for Datacom and Telecom applications.

Features

¡ñ Up to10km transmission on SMF

¡ñ Support Dual Rate 103.1G and 111.8Gbps

¡ñ Transmitter:4-lane*28Gb/s LAN-WDM EML TOSA   (1295.56nm,1300.05nm,1304.58nm,1309.14nm)

¡ñ Receiver:4-lane*28Gb/s PIN ROSA

¡ñ 10*10G Electrical Serial Interface (CAUI/OTL4.10)

¡ñ MDIO management interface with Digital Diagnostic

¡ñ CFP MSA package with duplex LC connector

   +3.3V power supply

¡ñ Power consumption less than 12W l   Operating case temperature: 0~+70°C 

Applications 

¡ñ 100GE Routers and Switches

¡ñ 100G DWDM/OTN

¡ñ 100G Network Security

Compliance 

¡ñ Compliant with IEEE 802.3ba 100GBASER-LR4 l  

¡ñ Compliant with ITU-T 411-9D1F

¡ñ Compliant with CFP MSA Hardware Specification Rev1.4

¡ñ Compliant with CFP MSA MDIO Specification Rev1.4 

Absolute Maximum Ratings

Parameter

Symbol

Conditions

Min.

Max.

Unit

Storage Temperature(Case)

TS

-40

+85

¡æ

Relative Humidity

RH

5

+85

%

Damage Threshold for Receiver

Pmax

£­

+10.0

dBm

Power Supply

Vcc

-0.3

+3.6

V

ESD Sensitivity on module and all host pins

HBM

Human Body model R=1.5K,

C=100pF

£­

2000

Specification

Recommended Operating Conditions

Parameter

Symbo¡ñ

Min.

Typical

Max.

Unit

Operating Case Temperature

Tc

0

£­

+70

¡æ

Supply voltage

 Vcc 3.3V

+3.14

+3.3

+3.47

V

Supply Current

Icc 3.3V

£­

£­

3.3

A

Power dissipation

P

£­

£­

12

W

Low Power dissipation

PLow

2

W

In-rush Curent

I-inrush

50

mA/us

Turn-off rush Curent

I-turnoff

-50

mA/us

Link Distance

L

2M

£­

10km

 

 

 

 

Important Notice

Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.

The publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.

Search

ÍøÕ¾µØͼ